Real-time detection of harmonic current, through instantaneous current tracking control, which can automatically track the harmonic change of load with a high controllability and fast response.
The filtering performance is not affected by system impedance. Resonance prediction control can effectively prevent capacitance attenuation and avoid resonance risk. It can be adjusted dynamically in single phase to improve load imbalance, restrain system oscillation and improve system stability. Passive branch can use zero-crossing switching.
Single cabinet integrates active and passive modules, active modules are seamlessly parallel, with capacity free to choose, arbitrary expansion, easy maintenance.
With perfect protections , features like overvoltage, undervoltage protection, overcurrent protection, overheat protection and comprehensive control protection, to ensure the long-term stable operation of the device without equipment overload.
Integrated control and unit integration, the whole equipment adopts an intelligent control unit to control the real-time filtering of the active filter module and the automatic switching of the passive compensation module.
Products |
Horizontal modules |
Vertical modules |
||
Basic Parameters |
||||
Rated voltage (V) |
200-400 |
|||
Rated frequency (Hz) |
46-54 |
|||
Overall efficiency |
97.80% |
|||
Grid structure |
Three-phase three-wire/three-phase four-wire |
|||
Circuit topology |
Three level |
|||
Performance Index |
||||
Compensation mode |
Harmonic Compensation, Reactive Compensation, Harmonic and Reactive Compensation, Unbalanced Compensation |
|||
Harmonic order |
2nd to 60th or designated |
|||
Filtering degree |
Full capacity |
|||
Filtering efficiency |
≥95% (under sufficient filter capacity) |
|||
Target power factor |
Can be set according to users’ actual needs |
|||
Control algorithm |
Instantaneous Reactive Power/FFT |
|||
IGBT switching frequency (kHz) |
≥20 |
|||
Cooling |
Forced air cooled |
|||
Noise (dB) |
≤65 |
|||
Protections |
Over-voltage, over-current, short circuit, over-temperature, frequency protection, pulse abnormal protection, soft switching, current limitation |
|||
Communication & Monitoring |
||||
Communication interface |
RS485/RS232/Ethernet |
|||
Communication protocol |
Modbus/ TCP/IP client |
|||
Display interface |
7 inch touch screen |
|||
Fault alarm |
Screen display and relay output |
|||
Dimensions (W x D x H) |
||||
APF capacity (A) |
LC branch capacity (kVAR) |
Horizontal modules |
Vertical modules |
|
25/50 |
30 x 4 |
800 x 800 x 2200 |
/ |
|
60 x 3 |
800 x 1000 x 2200 |
/ |
||
60 x 4 |
800 x 1000 x 2200 |
/ |
||
60 x 5 |
800 x 1000 x 2200 |
/ |
||
60 x 6 |
800 x 1000 x 2200 |
/ |
||
100 |
30 x 4 |
800 x 1000 x 2200 |
1000 x 1000 x 2200 |
|
60 x 3 |
800 x 1000 x 2200 |
1000 x 1000 x 2200 |
||
60 x 4 |
800 x 1000 x 2200 |
1000 x 1000 x 2200 |
||
60 x 5 |
1000 x 1000 x 2200 |
1000 x 1000 x 2200 |
||
60 x 6 |
1000 x 1000 x 2200 |
1000 x 1000 x 2200 |
||
Please contact SSE if any special capacity or dimension required |
||||
Environmental Requirements |
||||
Altitude |
≤2000m (special instructions required above 2000m) |
|||
Working temperature(℃) |
-10-45 |
|||
Working humidity |
≤90% non-condensation |
|||
IP level |